Skip to main content

Standard Water Quality Report

Download Raw Water Quality Data CSV

Sample Point - Glenn 17 Source

Download Sample Point Report CSV  /  Inflow: Yes / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (mg/L) Lab
2012-05-11--354.053.8----7.93350034.630.34--2.85--3.33--57.95--
2015-04-29--243.943.74----8.82960022.05<0.10--1.49--1.9--91.3<5--
2020-05-20estimated604.083.99----9.9257--ND23.64<0.10--1.21--1.82--77.6<5--
2023-05-08----3.73.85----10.43190<0.1050.360.23--1.81--4.9--117.69--
Minimum:0243.73.74----7.92570022.050.23--1.21--1.82--57.95--
Maximum:0604.083.99----10.43350050.360.34--2.85--4.9--117.69--
Average:0403.943.85----9.33020032.70.29--1.84--2.99--86.17.0--
Range:0360.380.25----2.5780028.310.11--1.64--3.08--59.74--
Median:03543.83----9.35307.50029.140.29--1.65--2.62--84.457--
Loading (lb/day):----12.660.14--0.83--1.09--

Sample Point Description: Raw untreated AMD for Glenn 17 passive system

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Sample Point - Glenn 17 Combined

Download Sample Point Report CSV  /  Inflow: No / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (mg/L) Lab
2020-05-20measured605.34.60----9.5225123.0111.82<0.10--1.16--1.29--79.2<5--
2023-05-08----3.994.27----9.22960<0.1044.16<0.10--1.62--5.17--113.46--
Minimum:0603.994.27----9.222503.0111.82----1.16--1.29--79.26--
Maximum:0605.34.60----9.5296123.0144.16----1.62--5.17--113.46--
Average:0604.654.44----9.42616.00328.0----1.39--3.23--96.36.0--
Range:001.310.33----0.37112032.34----0.46--3.88--34.20--
Median:0604.654.44----9.35260.563.0127.99----1.39--3.23--96.36--
Loading (lb/day):8.652.178.52----0.84--0.93--

Sample Point Description:

Combined discharge after 2019 rehab

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Sample Point - Glenn 17 ULWL

Download Sample Point Report CSV  /  Inflow: No / Outflow: Yes
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (mg/L) Lab
2012-05-11--7.76.466.41----7.84122530.32-14.130--2.05--1.28--137.47--
2015-04-29--124.424.26----8.22700019.34<0.10--1.49--1.93--87.9<5--
Minimum:--7.74.424.26----7.827000-14.130--1.49--1.28--87.97--
Maximum:--126.466.41----8.24122530.3219.340--2.05--1.93--137.47--
Average:--105.445.34----8.034112.50152.60--1.77--1.61--112.77.0--
Range:--4.32.042.15----0.41422530.3233.470--0.56--0.65--49.50--
Median:--9.855.445.34----834112.515.162.610--1.77--1.61--112.657--
Loading (lb/day):2.312.810.74----0.2--0.2--

Sample Point Description: effluent of Upflow Limestone Well Left

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Sample Point - Glenn 17 ULWR

Download Sample Point Report CSV  /  Inflow: No / Outflow: Yes
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (mg/L) Lab
2012-05-11--10.56.355.97----7.73761228.58-5.370--2.45--1.87--146.99--
2015-04-29--124.134.13----10.12780018.72<0.1--1.54--2.03--87.86--
Minimum:--10.54.134.13----7.727800-5.370--1.54--1.87--87.86--
Maximum:--126.355.97----10.13761228.5818.720--2.45--2.03--146.99--
Average:--115.245.05----8.93276.00146.70--2.00--1.95--117.47.5--
Range:--1.52.221.84----2.4981228.5824.090--0.91--0.16--59.13--
Median:--11.255.245.05----8.9327614.296.680--2--1.95--117.357.5--
Loading (lb/day):1.513.612.7----0.27--0.26--

Sample Point Description: Effluent of Upflow Limestone Well Right

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.