Water Quality Report


EXPORT RAW DATA TO CSV

Sandy Run SA0-D14 Water Quality Report - SA0-D14

Export Sample Point Report  /  Inflow: Yes / Outflow: No
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2021-06-08Bucket1943.453.21------7280<20.0134.74.26--1.51--10--154<0.800--
Minimum:01943.453.21------7280--134.74.26--1.51--10--154----
Maximum:01943.453.21------7280--134.74.26--1.51--10--154----
Average:01943.453.21------7280--134.704.26--1.51--10.00--154.0----
Range:--000------00--00--0--0--0----
Median:--1943.453.21------7280--134.74.26--1.51--10--154----
Loading (lb/day):----314.19.93--3.52--23.32--

Sample Point Description:

AMD; Influent to the SA0-D14 passive treatment system

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.


Sandy Run SA0-D14 Water Quality Report - SA0-D14-D

Export Sample Point Report  /  Inflow: No / Outflow: Yes
Date
Method of Flow
Flow - Field (gal/min)
pH - Field (S.U.)
pH - Lab (S.U.)
ORP - Field (mvolts)
DO - Field (mg/L)
Temp - Field (C)
Cond - Lab (umhos/cm)
Alkalinity - Field (mg/L)
Alkalinity - Lab (mg/L)
Acidity - Lab (mg/L)
T. Fe - Lab (mg/L)
D. Fe - Lab (mg/L)
T. Mn - Lab (mg/L)
D. Mn - Lab (mg/L)
T. Al - Lab (mg/L)
D. Al - Lab (mg/L)
SO4 - Lab (mg/L)
TSS - Lab (mg/L)
Ferrous Iron (Mg/L) Lab
2021-06-08Assumed1946.516.48------5614029.7-2.180.341--0.652--0.939--2224--
Minimum:01946.516.48------5614029.7-2.180.341--0.652--0.939--2224--
Maximum:01946.516.48------5614029.7-2.180.341--0.652--0.939--2224--
Average:01946.516.48------56140.0030-2.180.34--0.65--0.94--222.04.0--
Range:--000------00000--0--0--00--
Median:--1946.516.48------5614029.7-2.180.34--0.65--0.94--2224--
Loading (lb/day):93.2869.26-5.080.8--1.52--2.19--

Sample Point Description:

Final Effluent of the SA0-D14 passive treatment system

  1. Records with no value are not included in statistical calculations.
  2. Values lower than the minimum detection limit are assumed to be 0.
  3. Average pH is calculated using the arithmetic mean of pH values. Hydronium ion concentrations were not used.
  4. This work is licensed under the Creative Commons Attribution-NonCommercial-ShareAlike License.

To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-sa/2.5/ or send a letter to Creative Commons, 559 Nathan Abbott Way, Stanford, California 94305, USA.